CPR Clancy — Interactive CPR & First-Aid Training Manikin with Patented Head-Turn Mechanism
CPR Clancy — Interactive CPR & First-Aid Training Manikin with Patented Head-Turn Mechanism is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
Delivery and Shipping
Delivery and Shipping
All orders are despatched within 1-3 business days after order placed (please allow a couple of extra days during peak seasons and sale periods).
SHIPPING METHOD
Standard Shipping - 2-5 business days after despatch
Express Shipping - 1-2 business days after despatch
*Based on Aust Post suggested delivery times
CPR Clancy — Interactive CPR & First-Aid Training Manikin
CPR Clancy is a truly realistic, interactive, and inclusive CPR and first-aid training manikin, built to set a new benchmark in clinical simulation. Its patented head-turn, twist, and tilt mechanism delivers authentic cervical movement, letting first responders build verified clinical competence in critical airway positioning, log-roll technique, and trauma management, all in a single 3.5kg, easy-to-transport package.
Key Features
- Patented head-turn, twist, and tilt mechanism — authentic cervical movement for airway positioning, dynamic airway clearance, log-roll, and helmet-removal training
- HaptiCore™ adjustable back-lock system — dedicated Adult, Child, and Lock settings with auditory clicks and haptic feedback for precise, verified compression depth, including for vision- or hearing-impaired learners
- Dual chest overlay options — interchangeable flat and raised-breasted overlays for inclusive, gender-neutral CPR and AED placement training
- Log-roll and helmet-removal capability — integrated torso and head-turn mechanism supports multi-rescuer spinal alignment practice and safe motorcycle/bicycle helmet removal
- VentilFlow™ single-use hygiene bag system — disposable, contamination-free airway for every learner with rapid, safe changeovers
- Compact and portable — just 3.5kg total with both chest overlays, with a protective locking pack-down system for transit
- Neffy™ anaphylaxis training compatibility — nostrils designed to accommodate intranasal spray training with correct depth and placement
- NasoPort™ nasal cavity insert — simulates CSF leak, nosebleed management, and intranasal medication (e.g. Midazolam) delivery; removable for NPA sizing and placement demonstration (non-ventilatory)
- OtoCav™ ear simulation port — foreign body removal and suspected CSF discharge training
- Eye irrigation training — supports real-fluid eye-wash and irrigation technique practice
- Asthma puffer and spacer compatibility — mouth structure locks a standard puffer and spacer securely, and supports direct puffer administration without a spacer
- Aspirin administration simulation — via the VentilFlow system, for suspected cardiac event training
- Head bleed and bandaging zone — dedicated trauma zone from forehead to the back of the head for pressure bandage and head bundle practice
- Wound packing and trauma cavities — authentic upper and lower torso cavities for penetrating trauma and haemorrhage control training
- Chest seal application surface — dedicated upper-torso wound for practising chest seal application to help prevent tension pneumothorax
- Guedel (oropharyngeal) airway compatibility — for use in BVM ventilation scenarios
- BVM ventilation — supported supine, lateral, or with a tilted head
- Y-catheter and Yankauer suction training — suction around and through a Guedel airway, plus Yankauer suction practice using VentilFlow bags and simulated fluids
- Oxygen therapy (nasal cannula) — Clancy sits upright unassisted, with ear design providing a secure cannula anchor
- Soft and hard cervical collar compatibility — neck accommodates both collar types for immobilisation training
Specifications
| Total weight (with both chest overlays) | 3.5 kg |
| Chest overlay options | Flat and raised-breasted (interchangeable) |
| Compression feedback | HaptiCore adjustable back-lock — Adult, Child, and Lock settings; auditory and haptic feedback |
| Airway hygiene system | VentilFlow single-use disposable bag system |
| NPA training | Demonstration only — non-ventilatory |
FAQ Section
Q: What makes CPR Clancy different from a standard CPR manikin?
A: CPR Clancy features a patented head-turn, twist, and tilt mechanism for authentic cervical movement, an adjustable HaptiCore back-lock system with auditory and haptic compression feedback, interchangeable chest overlays for inclusive training, and dedicated zones for wound packing, chest seal application, and multiple airway and medication administration scenarios, all in a single 3.5kg manikin.
Q: Can CPR Clancy be used for log-roll and helmet-removal training?
A: Yes. Its integrated torso and patented head-turning mechanism support best-practice log-roll demonstrations for multi-rescuer teams, and the manikin allows for safe, realistic removal of motorcycle and bicycle helmets to practice cervical stabilisation.
Q: Does CPR Clancy support inclusive and gender-neutral training?
A: Yes. It features interchangeable flat and raised-breasted chest overlays, and the HaptiCore feedback system includes auditory and haptic cues designed to support vision- or hearing-impaired learners.
Q: What airway management skills can be practised on CPR Clancy?
A: Guedel (oropharyngeal) airway insertion, BVM ventilation in supine, lateral, or tilted-head positions, Y-catheter and Yankauer suctioning, nasopharyngeal airway (NPA) sizing and placement demonstration, and nasal cannula oxygen therapy.
Q: Can CPR Clancy be used for trauma and bleeding-control training?
A: Yes. It includes a dedicated head bleed and bandaging zone, authentic upper and lower torso wound-packing cavities for penetrating trauma, and a chest seal application surface to practise preventing tension pneumothorax.
Q: What medication administration scenarios can be simulated?
A: CPR Clancy supports asthma puffer and spacer training (including direct puffer administration without a spacer), Neffy intranasal spray training for anaphylaxis, intranasal Midazolam simulation via the removable NasoPort insert, and oral aspirin administration simulation via the VentilFlow system.
Q: How is hygiene maintained between students?
A: The VentilFlow single-use disposable bag system provides a contamination-free airway for every learner, enabling rapid, safe changeovers between students.
Q: How much does CPR Clancy weigh and how is it transported?
A: The manikin weighs just 3.5kg with both chest overlays, and uses a premium protective locking, pack-down design for transit between training locations.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.